Crane Moment Limiter ‘Error Code Meanings’
Crane Moment Limiter ‘Error Code Meanings’
Zoomlion Crane Computer Error Code Lookup Table. Error Code Meaning
E21, E31: Power supply short circuit, undervoltage.
E41: Pressure 1 voltage value invalid, valid range (0.45V - 4.8V)
E51: Pressure 2 voltage value invalid, valid range (0.45V - 4.8V)
E61: Arm length value invalid, valid range (10.4m - 39.2m)
E71: Angle value invalid, valid range (-6° - 84°)
E81: Cylinder I length value invalid, valid range (0m - 7.2m)
E91: Cylinder II length less than 0
E81: Cylinder I length value is less than 0